| Parameters |
| Mfr |
Amphenol NovaSensor |
| Series |
NPA-300 |
| Package |
Tape & Reel (TR) |
| Product Status |
Active |
| Applications |
Board Mount |
| Pressure Type |
Vented Gauge |
| Operating Pressure |
15PSI (103.42kPa) |
| Output Type |
Analog Voltage |
| Output |
2 V ~ 3 V |
| Accuracy |
±1.5% |
| Voltage - Supply |
3.135V ~ 3.465V |
| Port Size |
Male - 0.12" (3mm) Tube, Dual |
| Port Style |
Barbed |
| Features |
Amplified Output, Temperature Compensated |
| Termination Style |
Gull Wing |
| Maximum Pressure |
60PSI (413.69kPa) |
| Operating Temperature |
-40°C ~ 125°C |
| Mounting Type |
Surface Mount |
| Package / Case |
14-SOIC Module, Top Port |
| Supplier Device Package |
- |
| Base Product Number |
NPA-300B |
| RoHS Status |
RoHS Compliant |
| Moisture Sensitivity Level (MSL) |
5A (24 Hours) |
| ECCN |
EAR99 |
| HTSUS |
9026.20.4000 |
| Standard Package |
100 |
Pressure Sensor 15PSI (103.42kPa) Vented Gauge Male - 0.12" (3mm) Tube, Dual 2 V ~ 3 V 14-SOIC Module, Top Port